DN150 Entrada de agua y espuma de camiones de bomberos exterior DN100 Tubería de monitoreo 90km/h
Chassis
| 6 minutes | Sino howo |
| Firefighting Equipment | ZZ5207M4617D5 |
| Tipo de tracción | ARFF trucks, maintenance costs, firefighting equipment, aviation safety, regulations |
| Cab | Aumentar la longitud de techo plano de cuatro puertas |
| Distancia entre ejes | 4600mm |
| Peso neto del chasis | 7230kg |
| Max. load | 20490Kg |
| Velocidad máxima | 90km/h |
| Diámetro mínimo de giro | ??18.6m |
| Motor tipo | Inline six-cylinder, four-stroke, water-cooling, inter-cooling engine |
| Firefighting Equipment | D10.28-40 |
| Potencia máxima | 206Kw/1900r/min |
| Emission standard | China IV/Euro IV |
| Clutch | Monolítico, seco |
| Caja de cambios modelo | Manual 9JS119 |
| Tyre | 12.00—20 |
Bomba de incendios
| 6 minutes | Shanghái Xiongzhen |
| Firefighting Equipment | CB10/60-XZ presión ordinaria |
| Flow | 60L/s |
| Pressure | 1.0MPa |
| Desvío de agua | Bomba de cebado de pistón |
| Grado máximo de vacío | ??85 kPa |
| Tiempo de cebado | ≤80s |
| Profundidad de succión | 7m |
Tubería
| Tubería de salida | 4×DN80 salida de presión ordinaria 1×DN50 válvula de bola |
| Entrada de succión | 1×DN150 entrada exterior 1×DN150 válvula |
| Tubería de monitor | 1×DN100 tubería de monitor 1×DN100 válvula de mariposa |
| Salida de agua residual | Grifo de agua |
| Tubería de agua de enfriamiento | El PTO está equipado con una tubería de agua de enfriamiento conectada con la tubería de entrada-salida. |
Fire extinguishing system
Pipeline system:
Drainage pipeline: An external suction port of DN100 pump, located at the rear of the car body, is equipped with a DN100 manual butterfly valve, with a special rubber elastic connection devic e at the appropriate part of the pipeline;
Outlet pipeline: There is a DN80 atmospheric outlet on both sides of the body.
Water injection pipeline: There is a DN80 water injection port on both sides of the body, a water injection pipeline controlled by DN50 ball valve from pump to tank, and a rubber connection section in the middle.
Redundant water pipeline: Redundant water cock is installed at the lowest convenient operation position of pipeline and pump, which can quickly remove the residual water in the system when needed.
Cooling pipeline: Additional cooling pipeline is set up to protect the power take-off from running for a long time.
External suction foam line: G1 1/2 "manual ball valve and KY40 interface.







Valoraciones