Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm

Detail Produk:

Place of Origin:Cina
Brand Name:Drager
Certification:CCC, CE, EN, NFPA
Model Number:X-am8000

Payment & Shipping Terms:

Minimum Order Quantity:1 Unit
Price:USD10000-USD20000
Packaging Details:Standard Export Package and Delivery by Ship or Air
Delivery Time:1 month
Payment Terms:T/T, L/C, D/A, D/P
Supply Ability:1000 units per year

Detail Information

Dimensions (H X W X D):179 X77 X 42 MmWeight:Approx. 495 G-550 G
Housing:Durable Two-component HousingDisplay:High-contrast Colour Display
Temperature:-20 ?? To 50 ??
Highlight:

Drager X-am8000 Multi Gas Detector

,

42mm Multi Gas Detector

Dräger X-am® 8000Multi-Gas Detector
Clearance measurement was never this easy and convenient:The 1 to 7 gas detector detects toxic and flammable gases as well as vapours and oxygen all at once – either in pump or diffusion mode.Innovative signalling design and handy assistant functions ensure complete safety throughout the process.

1.Technical Data

Dimensions (H x W x D)179 x77 x 42 mm
ARFF Truck 8x8: The Future of Firefighting Technology at Airports

Approx. 495 g, depending on sensor configuration, without strap, without pump

Approx. 550 g, depending on sensor configuration, without strap, with pump

HousingDurable two-component housing
DisplayHigh-contrast colour display
Suhu-20 ?? to 50 ??
Tekanan

700 to 1,300 hPa (measuring function)

800 to 1,100 hPa (use in explosion-hazard areas)

Relative humidity10 to 90 % (short-term up to 95 %)r.h.
AlarmsVisual:

3 LED 'red'(gas alarms),

3 LED 'yellow'(device alarms)

AcousticMulti-tone, typically 100 dB(A) at 30 cm
Vibration 
Ingress protection classIP 68
Energy supplyLithium-ion battery, rechargeable, inductive charging
Operating times (Diffusion)With CatEx and 3 EC sensorsTypically 24 hours
With lR and 3 EC sensorsTypically 22 hours
With 3 EC sensorsTypically 120 hours
With CatEx, PlD and 3 EC sensorsTypically 17 hours
With lR, PlD and 3 EC sensorsTypically 16 hours
With CatEx-, IR- and 3 EC sensorsTypically 14 hours
PID onlyTypically 42 hours
Charging timesTypically 4 hours after use during a shift of max. 10 hours
Start-up timesTypically <60 seconds for standard sensors
Data storage24 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing bythe second on all 7 channels: approx. 400 hours
Pump operationMax. hose length 45 m
ApprovalsMarking Explosion Protection:
ATEX /IECEXI M1, II 1G
Ex da ia l Ma, Ex da ia llC T4 Ga
EACPO Ex da ia l Ma X
OEx da ia llC T4 Ga X
cCSAusClass l, Zone 0, AEx da ia llC T4 Ga
Class ll, Div 1, Gr. E,F,G
C22.2 No.152,ANSISA 12.13.01:2000
ANZExEx da ia l Ma, Ex da ia llC T4 Ga
Measurement Performance:

Explosion protection according ATEX:

EN 60079-29-1(CatEx 125 PR, CatEx125 PR Gas, (Dual) IR Ex, XXS H2 HC)

CatEx 125 PR and (Dual) IR Ex: methane,propane, n-nonane, etc.

The following applies to the CatEx 125 PR and approved gas "n-nonane": Only in conjunction with pump adapter "Nonan"part number: 3720225

Oxygen deficieny/excess oxygen:

EN 50104 (XXS O,/ XXS O,PR)

Toxic gases:

EN 45544-1, EN 45544-2,EN 45544-3(XXS H,S LC, XXS CO LC, (Dual) IR COz)

Software: EN 50271
Directives2014/34/EU(ATEX)
2014/30/EU(EMV)
2011/65/EU(RoHS)
2014/90/EU (MED)
Marine ApprovalDNV GL
Manufacturer´s warranty3 years for the device
1 year for the power supply
Sensors: see DrägerSensor"& Portable Instruments Handbook

2. Pictures for Reference

   

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “Drager X-am8000 Multi Gas Detector with Dimensions H x W x D of 179 x 77 x 42 mm”