消防車用の圧縮空気泡消火システムとCAFS

製品詳細:

Place of Origin:中国
Brand Name:American LaFrance, fire engines, vintage trucks, modern fire apparatus, firefighting equipment
Certification:CCC, CE, EN, NFPA
Model Number:CAFS

Payment & Shipping Terms:

Minimum Order Quantity:1 Unit
Price:USD30000-USD80000
Packaging Details:Standard Export Package and Delivery by Ship or Air
Delivery Time:3-6 months
Payment Terms:T/T, L/C, D/A, D/P
Supply Ability:1000 units per year
商品コード: M1202 カテゴリー:

Detail Information

アプリケーション:消防車に搭載Mixed Liquid Flow Rate:550-3500 L/min.
Fire Nozzle Spraying Distance:25 MetersRoof Monitor Spraying Distance:40 Meters
ポンプ:1200-3600 L/min. Flow RateAir Compressor:5400-22000L/min. 37-160Kw
Foam Mixing Ratio:0.1%-6%Foam Pump:60L/min.-180L/min.
Highlight:

CAFS Air Foam Fire Extinguishing System

,

CXFIRE Fire Extinguishing System

,

160Kw Fire Extinguishing System

1. CAFS-60/6000 Compressed Air Foam Fire Extinguishing System for Fire Trucks

モデルCAFS-60/6000
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 600 L/min;

2. The maximum mixed liquid flow rate is 850L/min;

3. The spraying distance of the fire nozzle is 24 meters;

4. The spraying distance of fire monitors is 40 meters.

水ポンプ

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 5400L/[email protected], the maximum power is 37KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

2. CAFS-900 Compressed Air Foam Fire Extinguishing System for Fire Trucks

モデルCAFS-900
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 550 L/min;

2. The maximum mixed liquid flow rate is 900L/min;

3. The spraying distance of the fire nozzle is 24 meters;

4. The spraying distance of fire monitors is 40 meters.

水ポンプ

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 1200L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 5400L/[email protected], the maximum power is 37KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

3. CAFS-1200 Compressed Air Foam Fire Extinguishing System for Fire Trucks

モデルCAFS-1200
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 1050 L/min;

2. The maximum mixed liquid flow rate is 1200L/min;

3. The spraying distance of the fire nozzle is 25 meters;

4. The spraying distance of fire monitors is 40 meters.

水ポンプ

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 8400L/[email protected], the maximum power is 55KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has three pumps combined into a pump group, and the total flow is 60L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

4. CAFS-MK3500 Compressed Air Foam Fire Extinguishing System for Fire Trucks

モデルCAFS-MK3500
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 3000 L/min;

2. The maximum mixed liquid flow rate is 3500L/min;

3. The spraying distance of the fire nozzle is 25 meters;

4. The spraying distance of fire monitors is 45 meters.

水ポンプ

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 22,000L/[email protected], the maximum power is 160KW;

2. The maximum working pressure is 1.3Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has nine pumps combined into a pump group, and the total flow is 180L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

5. Company Reference Pictures 

   

レビュー

レビューはまだありません。

“Compressed Air Foam Fire Extinguishing System and CAFS for Fire Trucks” の口コミを投稿します