Compressed Air Foam Fire Extinguishing System and CAFS for Fire Trucks

产品详情:

原产地:中国
品牌名称:CXFIRE
认证:CCC, CE, EN, NFPA
型号:CAFS

付款与运输条款:

最小订单数量:1台
价格:USD30000-USD80000
包装详情:标准出口包装,按船或空运交付
交货时间:3-6 months
付款条款:T/T, L/C, D/A, D/P
供应能力:每年1000台
SKU: M1202 分类:

详细信息

应用:安装在消防车上Mixed Liquid Flow Rate:550-3500 L/min.
Fire Nozzle Spraying Distance:25 MetersRoof Monitor Spraying Distance:40 Meters
水泵:1200-3600 L/min. Flow RateAir Compressor:5400-22000L/min. 37-160Kw
Foam Mixing Ratio:0.1%-6%Foam Pump:60L/min.-180L/min.
突出特点:

CAFS Air Foam Fire Extinguishing System

,

CXFIRE Fire Extinguishing System

,

160Kw Fire Extinguishing System

1. CAFS-60/6000 Compressed Air Foam Fire Extinguishing System for Fire Trucks

模型CAFS-60/6000
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 600 L/min;

2. The maximum mixed liquid flow rate is 850L/min;

3. The spraying distance of the fire nozzle is 24 meters;

4. The spraying distance of fire monitors is 40 meters.

水泵

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 5400L/[email protected], the maximum power is 37KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

2. CAFS-900 Compressed Air Foam Fire Extinguishing System for Fire Trucks

模型CAFS-900
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 550 L/min;

2. The maximum mixed liquid flow rate is 900L/min;

3. The spraying distance of the fire nozzle is 24 meters;

4. The spraying distance of fire monitors is 40 meters.

水泵

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 1200L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 5400L/[email protected], the maximum power is 37KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

3. CAFS-1200 Compressed Air Foam Fire Extinguishing System for Fire Trucks

模型CAFS-1200
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 1050 L/min;

2. The maximum mixed liquid flow rate is 1200L/min;

3. The spraying distance of the fire nozzle is 25 meters;

4. The spraying distance of fire monitors is 40 meters.

水泵

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 8400L/[email protected], the maximum power is 55KW;

2. The maximum working pressure is 1.5Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has three pumps combined into a pump group, and the total flow is 60L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

4. CAFS-MK3500 Compressed Air Foam Fire Extinguishing System for Fire Trucks

模型CAFS-MK3500
Flow Rate and Spray Performance

1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 3000 L/min;

2. The maximum mixed liquid flow rate is 3500L/min;

3. The spraying distance of the fire nozzle is 25 meters;

4. The spraying distance of fire monitors is 45 meters.

水泵

1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds.

2. Rated flow: 3600L/min; Rated pressure: 1Mpa.

Air Compressor

1. The maximum flow is 22,000L/[email protected], the maximum power is 160KW;

2. The maximum working pressure is 1.3Mpa;

3. The cooling method is water-cooled, with over-temperature automatic protection device.

Foam Mixing Ratio Unit

1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %;

2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has nine pumps combined into a pump group, and the total flow is 180L/min.

Electric Control UnitComposed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus.

5. 公司参考图片 

   

评价

目前还没有评价

成为第一个“Compressed Air Foam Fire Extinguishing System and CAFS for Fire Trucks” 的评价者